Catalog
Scientific Research Institute of Technologies, Control and Diagnostics of Railway Transport

DC traction electric motor testing station

DC traction motors testing station
Articul: 55DK.421413.002

FUNCTIONAL CAPABILITIES

  • The station supports the following testing modes as per GOST 2582-2013:

    • measurement of windings DC resistance;
    • heating-up testing with one-hour exposure;
    • check of rated parameters and speed reversal;
    • high frequency testing;
    • testing for turn-to-turn insulation strength;
    • measurement of motor commutator run-out;
    • check of commutation;
    • measurement of winding insulation resistance to case and be tween windings;
  • The station automatically generates the following reports:

    • electronic test report;
    • database with information on all the tested electrical machines.
PERFORMANCE
Description Value
Linear converter:
Supply mains parameters 3 ~ 380 V, 50 Hz
Maximum apparent power 330 kVA
Maximum output voltage 2100 V
Maximum output current 150 A
Linear converter:
Supply mains parameters 3 ~ 380 V, 50 Hz
Maximum apparent power 330 kVA
Maximum output voltage 150 V
Maximum output current 1450 A
Converter:
Supply mains parameters 3 ~ 380 V, 50 Hz
Maximum apparent power 2 × 40 kVA
Maximum output voltage 2 × 45 V
Maximum output current 2 × 850 A
Automation and measurement unit:
Control circuits supply voltage 220В
Automatic equipment circuits supply voltage = 24В