FUNCTIONAL CAPABILITIES
- The station supports the following testing modes as per GOST 2582-2013:
-
- measurement of windings DC resistance;
- heating-up testing with one-hour exposure;
- check of rated parameters and speed reversal;
- high frequency testing;
- testing for turn-to-turn insulation strength;
- measurement of motor commutator run-out;
- check of commutation;
- measurement of winding insulation resistance to case and be tween windings;
- The station automatically generates the following reports:
-
- electronic test report;
- database with information on all the tested electrical machines.
PERFORMANCE
Description | Value |
---|---|
Linear converter: | |
Supply mains parameters | 3 ~ 380 V, 50 Hz |
Maximum apparent power | 330 kVA |
Maximum output voltage | 2100 V |
Maximum output current | 150 A |
Linear converter: | |
Supply mains parameters | 3 ~ 380 V, 50 Hz |
Maximum apparent power | 330 kVA |
Maximum output voltage | 150 V |
Maximum output current | 1450 A |
Converter: | |
Supply mains parameters | 3 ~ 380 V, 50 Hz |
Maximum apparent power | 2 × 40 kVA |
Maximum output voltage | 2 × 45 V |
Maximum output current | 2 × 850 A |
Automation and measurement unit: | |
Control circuits supply voltage | 220В |
Automatic equipment circuits supply voltage | = 24В |
Similar products
You have recently viewed

Articul: 55DK.421457.020 Train-Stop Equipment Monitoring and Diagnostics System “Doktor-060AT”

Articul: 55DK.411415.001 Collector Bows Monitoring and Diagnostics System “Doktor-060PG”

Articul: 55DK.411714.001 Production Package of Computer-Aided Load Testing of “Kiparis-5”

Articul: 55DK.411182.001 Electrical Insulation Resistance, Moisture Content and Ageing Meter “Kedr-2”

Articul: 55DK.441439.001 Computer-Aided Station for Adjustment of High-Pressure Fuel Pumps of Diesel Engines

Articul: 55DK.441439.005 Computer-Aided Station for Running Tests, Adjustment and Setup of the Speed Regulator

Articul: 55DK.441439.004 Computer-Aided Station for Check of Barrel/Plunger Assemblies Tightness